Product

7-language support
Automatic tuning
2 Integrated limit switches (1 mA or 4 mA output for open or closed indication)
Integrated valve position transmitter (4-20mA output)
NAMUR mounting
Compact size for small valves and tight spaces
HART Communicating

Full Usable Capacity
Internal Relief
Smart Bleed
Integral Filter
Ease of Maintenance
Rugged Construction

Simple circuit
Easy to maintain
Moisture resistance
Reversible field operation

Reference accuracy: ± 0.5% of the total scale of the output range; Including lag, linearity and dead zone combined effects
Independent linearity: ± 0.5% of the total scale of the output range
Lag: 0.4% of the total scale of the output range

Area classification: intrinsically safe, explosion-proof, dust-proof, fire-proof, non-flammable, N-type
Data interface: wired
Power supply: Loop power supply (two-wire system)
Process control: Liquid level

Suffix Codes : H = With HART communication [Release: R1.02.00]
Suffix Codes : 5 = For pressure clamp terminal block or MIL cable with no explosion protection
Suffix Codes : 3 = With ISA Standard G3 and temperature (-20 to 70 ºC)
Shipping weight : 1.5 Kg

The design is small, strong and light, easy to install
Process isolation diaphragm: Stainless steel, Hastelloy C, Monel, Tantalum (CD, CG only) and gold plated Monel
It can ensure the accuracy and stability under different working conditions

Two detectors enable continuous measurement without interruption during maintenance
Reducing maintenance/instrumentation costs through HART communications
Backup system with two detectors for higher reliability measurements
pH/ORP, conductivity, and dissolved-oxygen detectors can be connected to two of the same type

Adaptable sensors withstand high vibration industry applications
The DIN sensor connector allows for quick connection and replacement
Measuring Instrument Instruction (MID) calibration options are suitable for trade handover applications
Hazardous site certification meets local needs

Commission and validate devices faster
Automatically synchronize field changes
with AMS Device Manager
Configure and test valves inline
Intrinsically safe; usable anywhere you need to go

Direct Switch Technology and Probe End Projection
Wide Range of Probe Styles, Materials, and Temperatures and Pressures
Advanced Diagnostics Options
Transmitter Verification and High Level Supervision Options

Dual input
0/4-20mA current output
Temperature compensated
HART & Profibus DP digital communications available