Rosemount 499ACL Chlorine Sensor

Rosemount 499ACL Chlorine Sensor


Measure free chlorine without sample pre -processing
No messy and expensive reagents need
Automatic school correction to at least pH 9.5
Easy to replace the membrane; no tools need

Send Inquiry

Rosemount 499ACL-01-54 chlorine sensor


1. Product description

499ACL is used to measure the membrane cover current sensor series of free chlorine, total chlorine and one -chlorine. Free chlorine sensor 499ACL-01 does not require sample pre-processing or expensive reagent to maintain. Total chlorine sensor, 499ACL-02, no need to use the standard reagent sampling system for pH correction. MonochLoramine sensor, 499acl-03 without using reagents or samples for measurement. All three sensors have an easy -to -replace film, without tools.


2. Product specifications

1 pound/ 3 pounds (0.5 kg/ 1.5 kg)

The measurement range is 0 to 10 ppm (mg / L) to CL 2. For a higher range, please consult our company

The size is 25 feet (7.6 meters) 300 feet (91 meters)

1 pound/ 3 pounds (0.5 kg/ 1.5 kg)

The measurement range is 0 to 10 ppm (mg / L) to CL 2. For a higher range, please consult the factory


3. characteristics

Measure free chlorine without sample pre -processing

No messy and expensive reagents need

Automatic school correction to at least pH 9.5

Easy to replace the membrane; no tools need

Automatic compensation membrane permeability with changes in temperature

Automatic pressure balance maintains correct membrane tension

VarioPol connector option allows replacement sensors without using new cables


c598e3915d7c50b36cdcc311c64505b.png

Accessories

Current/optics

9210299: The current sensor adds the solution #3, 4 OZ (125 ml)

9210392: Reference filling gel HT, silicon, 30 ml

9210424: SC injection kit, 30 CC syringe (4 to 5 times per pipe can be added)

23502-00: diaphragm component, O-shaped circle, DO, 3

23502-02: diaphragm component, with O -shaped circle, total chlorine, (code -02), 3, 3

23502-04: diaphragm component, O-shaped circle, TRDO, 3

23502-08: diaphragm component, O-shaped circle, residual chlorine, (code -01-54), 3

23502-10: There is no need to auxiliary pH sensor's residual chlorine diaphragm components, including 3 diaphragm components and O-shape circles

23502-11: diaphragm component, O-shaped circle, ozone, 3

9210264: The current sensor adds the solution #1, 4 OZ (125 ml)

9210356: The current sensor adds the solution #4,125 ml (code -01)

33521-00: diaphragm positioner

33521-02: diaphragm positioner

33523-00: Plug

33523-02: Plug

R0084230: RDO Pro sensor cover replacement kit

R0084230X: RDO Pro-X sensor cover replacement kit

R0086460X: RDO Pro-X sensor, with 10 m cable

R0094030: RDO Pro analyzer, AC power supply